179 research outputs found

    Development of a TDC to equip a Liquid Xenon PET prototype

    Full text link
    A Time to Digital Converter was designed (CMOS 0.35 $\mum) in order to be used in Liquid Xenon PET prototype. The circuit proved to be able to work at -120 degrees C, while showing a resolution of 250 ps. The circuit enables a low readout dead time (<90 ns) and provides a fully synchronous digital interface for easy data retrieval.Comment: 4 pages, submitted to IEEE Transactions on Nuclear Scienc

    An integrated CMOS time-to-digital converter for coincidence detection in a liquid xenon PET prototype

    No full text
    A Time to Digital Converter was designed (CMOS 0.35 ÎĽm) to perform coincidence detection in a Liquid Xenon PET prototype. This circuit proved to be able to operate at 150 K, while showing a resolution better than 250 ps. The circuit enables a low readout dead time (<90 ns) and provides a fully synchronous digital interface for easy data retrieval

    A low power 12-bit and 25-MS/s pipelined ADC for the ILC/Ecal integrated readout

    No full text
    International audienc

    Linac modeling for external beam radiotherapy quality assurance using a dedicated 2D pixelated detector

    No full text
    International audienceQuality assurance is a key issue in intensity modulated radiotherapy. Errors can occur in the dose delivery process induces significant differences between the planned treatment and the delivered one. In this context, the Medical Application Physics group of the LPSC is developing TraDeRa (Transparent Detector for Radiotherapy), a 2D pixelated matrix of ionization chambers located upstream to the patient. The signal map obtained with TraDeRa has to be processed to provide medical observables to quantify the quality of the treatment delivery. This relies on accurate Monte Carlo simulations benchmarked with measurements performed under a linear accelerator (Linac).The work described in this paper lies in the optimization of the Linac head simulation and the development of an innovative Monte Carlo/measurements comparison method to perform an accurate enough model of the X-ray production device. An optimized parametrization of the particles transport allowed an increase of the simulation efficiency by a factor 3. The characteristics of an electron beam of a reference Linac were matched with the simulation results by using dose deposition of the created X-ray beam in a water tank. Two parameters are particularly critical: the nominal energy of the electrons and the radial distribution of impact on the target. The innovative method was able to provide within minutes those two parameters for any Linac, achieving, for example, a 10 keV precision on the energy determination for a 6 MV operating Linac

    GePEToS : A Geant4 Monte Carlo simulation package for Positron Emission Tomography

    Full text link
    GePEToS is a simulation framework developed over the last few years for assessing the instrumental performance of future PET scanners. It is based on Geant4, written in Object-Oriented C++ and runs on Linux platforms. The validity of GePEToS has been tested on the well-known Siemens ECAT EXACT HR+ camera. The results of two application examples are presented : the design optimization of a liquid Xe micro-PET camera dedicated to small animal imaging as well as the evaluation of the effect of a strong axial magnetic field on the image resolution of a Concorde P4 micro-PET camera.Comment: 5 pages, 12 figures, submitted to IEEE Transactions on Nuclear Scienc

    Experimental results and first 22Na source image reconstruction by two prototype modules in coincidence of a liquid xenon positron emission tomograph for small animal imaging

    No full text
    International audienceA detector with a very specific design using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Two prototype modules equipped with Position Sensitive Photo Multiplier Tubes (PSPMTs) operating in the VUV range (178 nm) and at 165 K were built and studied in coincidence. This paper reports on energy, time and spatial resolution capabilities of this experimental test bench. Furthermore, these experimental results were used to perform the first image reconstruction of a 22Na source placed in the experimental setup

    Experimental study of a liquid Xenon PET prototype module

    Get PDF
    A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon properties. It does feature a promising insensitive to any parallax effect. This work reports on the performances of the first LXe prototype module, equipped with a position sensitive PMT operating in the VUV range (178 nm).Comment: Proc. of the 7th International Workshops on Radiation Imaging Detectors (IWORID-7), Grenoble, France 4-7 July 200
    • …
    corecore